Journals / Turkish Journal of Veterinary and Animal Sciences / 2017 / Cilt: 41 - Sayı: 2

Electroencephalographic electrode montage in goats: topographical, radiological, and physiological assessment

Pages
265–272
Publication Date
2017-04-19
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The results indicated right hemisphere conservatism and an attentional process during the resting phase in goats.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:The paucity of information on assortment of EEG leads in goats has hampered analysis of brain regional activity during different physiological, pathological, and ethological conditions in this species.
📊
Key Findings & Data:Ten specimens of freshly slaughtered goat heads (crossbreed of Jamunapari) were procured and preserved at -20 °C.
💡
Conclusion & Impact:The results indicated right hemisphere conservatism and an attentional process during the resting phase in goats.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Electroencephalography · montage · goat

Abstract

The paucity of information on assortment of EEG leads in goats has hampered analysis of brain regional activity during different physiological, pathological, and ethological conditions in this species. Hence, the present study was designed to develop a montage with suitable combinations of EEG electrode arrays in goats. Ten specimens of freshly slaughtered goat heads (crossbreed of Jamunapari) were procured and preserved at -20 °C. Frozen samples were sliced sagittally and transversely to corroborate the link between intended topographic landmarks for EEG leads over the scalp and underlying provinces of the brain. Based on these observations, nine sites for EEG electrode placement were finalized so as to include the entire cerebral cortex. These electrode placement sites were further checked through another set of five goat heads. The electrode sites were then extrapolated to live animals for radiological (orthogonally) and physiological validation. The montage derived on basis on these electrode placement sites provided maximum brain coverage and they were found suitable for EEG in goats. Parietal and vertex areas of the brain were found to be most active during the resting phase with the right hemisphere exhibiting more activity than the left. The results indicated right hemisphere conservatism and an attentional process during the resting phase in goats.

🔖

Cite This Article

MADAN, A. K., RASTOGI, S. K., DAS, A. K., KORDE, J. P., SINGH, İ., SINGH, G. K. (2017). Electroencephalographic electrode montage in goats: topographical, radiological, and physiological assessment. Turkish Journal of Veterinary and Animal Sciences, Cilt: 41 - Sayı: 2, 265–272. https://ajindex.com/articles/121509

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (12)

  1. Haberham ZL, van den Brom WE, Venker-van Haagen AJ, Baumans V, de Groot HNM, Hellebrekers LJ. EEG evaluation of reflex testing as assessment of depth of pentobarbital anesthesia in the rat. Lab Anim 1999; 33:47-57.
  2. Stienen PJ, Haberham ZL, van den Brom WE, de Groot HNM, Venker-Van Haagen AJ, Hellebrekers LJ. Evaluation of methods for eliciting somatosensory-evoked potentials in the awake, freely moving rat. J Neurosci Methods 2003; 126: 79-90.
  3. Tortella FC, Rose J, Robles L, Moreton JE, Hughes J, Hunter JC. EEG spectral analysis of the neuroprotective Kappa opioids Enadoline and PD117302. J Pharm Exp Ther 1997; 282: 286- 293. Holliday TA, Williams C. Clinical electroencephalography in case of dogs. Vet. Neurol Neurosurg J 1999; 1: 1. Murrell J, Johnson CB, White KL, Taylor PM, Haberham ZL, Waterman-Pearson AE. Changes in the EEG during castration in horses and ponies anaesthetized with halothane. Vet Anesth Analg 2003; 30: 138-146.
  4. Bergamasco L, Macchia E, Facelloa C, Badinob P, Odoreb R, Pagliassob S, Bellinob C, Osellab MC, Reb G. Effects of brief maternal separation in kids on neurohormonal and electroencephalographic parameters. Appl Anim Behav Sci 2005; 93: 39-52.
  5. Suzuki M, Sitizyo K, Takeuchi T, Saito T. Electroencephalogram of Japanese black calves affected with cerebro-cortical necrosis. Japanese Journal of Veterinary Science 1990; 52: 1077-1087.
  6. Orth M, Barter L, Dominguez C, Atherley R, Carstens C, Antognini JF. Halothane and propofol differentially affect electroencephalographic responses to noxious stimulation. Br J Anaesth 2005; 95: 477-484.
  7. Jongman EC, Morris JP, Barnett JL, Hemsworth PH. EEG changes in 4-week old lambs in response to castration, tail docking and mulesing. Aust Vet J 2000; 78: 339-343.
  8. Ong RM, Morris JP, O’Dwyer JK, Barnett JL, Hemsworth PH, Clarke IJ. Behavioral and EEG changes in sheep in response to painful acute electrical stimuli. Aust Vet J 1997; 75: 189-193.
  9. Huozha R, Rastogi SK, Korde JP, Madan AK. Electroencepholographic changes during experimental pain induction in goats. Vet Arhiv 2011; 81: 359-368.
  10. Madan AK, Korde JP, Das AK, Rastogi SK. Propofol-induced electroencephalographic, electrocardiographic and spirometric changes in goats. Vet Arhiv 2010; 80: 27-39.
  11. Anand M, Korde JP, Rastogi SK, Madan AK. Electroencephalographic studies on cross bred (local × Jamunapari) female goats subjected to different feeding practices. Indian J Anim Res 2013; 47: 236-239.
  12. Olopade JO, Onwuka SK, Balogun BA, Oke BO. Morphometric inve