The Case of Removal of Intracoronary Broken Stent Catheter’s Shaft and Its Balloon Trough Femoral Sheat During Primer PTCA

Hakan Göçer(Private Edremit Korfez Hospital)0000-0002-9644-9579
Mohammed Abusharekh(İzmir Medikal Park Hastanesi)0000-0002-4546-0479
Ahmet Barış Durukan(Medigüneş Hastanesi,Kardiovasküler Cerrahi Kliniği)0000-0003-0566-0350
Pages
—
Publication Date
2022-03-31
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

After successfully catch and removal of broken part of stent catheter, patient’s situation was going well and discharged with medical therapy shortly after intervention

📌 3 Key Takeaways

🎯
Objective & Hypothesis:In the time of invasive area, catheter based complications is getting more frequent and interventionist deals with this kind of complications’ management more than vascular surgeons.
📊
Key Findings & Data:But the patient stability deteriorates the time of complications especially result of intracoronary foreign bodies.
💡
Conclusion & Impact:After successfully catch and removal of broken part of stent catheter, patient’s situation was going well and discharged with medical therapy shortly after intervention
🔬Design:Case Report
📍Scope:Comprehensive Sample
⚙️Variables:Complication · Coronary Artery Stenting · Snare

Abstract

In the time of invasive area, catheter based complications is getting more frequent and interventionist deals with this kind of complications’ management more than vascular surgeons. Regardless of complication’s nature commonly management of complications are successful and requirements of surgery are needless. But the patient stability deteriorates the time of complications especially result of intracoronary foreign bodies. Quick Removal of these foreign bodies from coronary circulation can stabilize patient condition. After that externalization of these kind remnants from patient body is the final step of successfully management of complications. . We herein present an acute inferior ST elevation myocardial infarction (MI) with hemodynamic disturbance because of total obstruction of RCA with broken stent balloon shaft. After successfully catch and removal of broken part of stent catheter, patient’s situation was going well and discharged with medical therapy shortly after intervention

Özet

In the time of invasive area, catheter based complications is getting more frequent and interventionist deals with this kind of complications’ management more than vascular surgeons. Regardless of complication’s nature commonly management of complications are successful and requirements of surgery are needless. But the patient stability deteriorates the time of complications especially result of intracoronary foreign bodies. Quick Removal of these foreign bodies from coronary circulation can stabilize patient condition. After that externalization of these kind remnants from patient body is the final step of successfully management of complications. . We herein present an acute inferior ST elevation myocardial infarction (MI) with hemodynamic disturbance because of total obstruction of RCA with broken stent balloon shaft. After successfully catch and removal of broken part of stent catheter, patient’s situation was going well and discharged with medical therapy shortly after intervention.

🔖

Cite This Article

Göçer, H., Abusharekh, M., Durukan, A. B. (2022). The Case of Removal of Intracoronary Broken Stent Catheter’s Shaft and Its Balloon Trough Femoral Sheat During Primer PTCA. Celal Bayar Üniversitesi Sağlık Bilimleri Enstitüsü Dergisi, Volume: 9 Issue: 1. https://doi.org/10.34087/cbusbed.934415

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (5)

  1. Mitomo S, Naganuma T, Takagi K. Comparison between plain old balloon angioplasty and drug eluting stent implantation for the treatment of stent fracture. J Interven Cardiol. 2015;28:365–373.
  2. Wani SP, Rha SW, Park JY, Poddar KL, Wang L, Ramasamy S, et al. A novel technique for retrieval of a drug-eluting stent after catheter break and stent loss. Korean Circ J. 2010;40:405–409.
  3. Rafighdust A, Eshraghi A. Acute ST-Elevation Myocardial Infarction after Coronary Stent Fracture. J Tehran Heart Cent. 2015;10:205-207. 4. Nakazawa G, V Finn AV, Vorpahl M, Ladich E, Kutys R, Isidora Balazs I. Incidence and predictors of drug eluting stent fractures in human coronary artery: a pathologic analysis. J Am Coll Cardiol 2009;54:1924–1931.
  4. Senior J, Guillamo MR, Ghattas A, Tapp L. Dislodged Coronary Artery Stent Retrieved With an Endovascular Snare. Tex Heart Inst J. 2020;47:213-215.
  5. Franklyn C-A, Melanie M-F, Anthony G-M. Coronary stent embolization during percutaneous coronary intervention: Successful retrieval using twisting guide wire technique by radial approach,Journal of Cardiology Cases. 2021;23:1878-5409.