Journals / Turkish Journal of Medical Sciences / 2019 / Cilt: 49 - Sayı: 1

Serum endocan level and diastolic functions in the case of lead exposure

Pages
66–73
Publication Date
2019-02-01
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Due to sharing a similar mechanism, a higher serum level of endocan may be a valuable laboratory clue for impaired diastolic function in this population.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Lead can cause morphological and functional changes in heart, and inflammation and endothelial dysfunction in vasculature.
📊
Key Findings & Data:This study investigated the relationship between lead exposure, endocan levels, and diastolic functions.Materials and methods: A total of 51 lead-exposed workers without a known cardiovascular disease or risk factors and 54 healthy controls were enrolled.
💡
Conclusion & Impact:Due to sharing a similar mechanism, a higher serum level of endocan may be a valuable laboratory clue for impaired diastolic function in this population.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Lead exposure · endocan · diastolic function

Abstract

Lead can cause morphological and functional changes in heart, and inflammation and endothelial dysfunction in vasculature. Endocan, as a novel indicator of endothelial dysfunction, has been used for cardiovascular diseases. This study investigated the relationship between lead exposure, endocan levels, and diastolic functions.Materials and methods: A total of 51 lead-exposed workers without a known cardiovascular disease or risk factors and 54 healthy controls were enrolled. All participants underwent transthoracic echocardiography. Blood lead and serum endocan levels were analyzed.Results: Baseline demographic and clinical characteristics were found to be similar between groups. Median blood lead (32 vs 1.5 µg/dL, P < 0.001) and serum endocan levels (67 vs 57.1 pg/mL, P = 0.02) were significantly higher in the lead-exposed group. Serum endocan level showed a positive correlation with blood lead levels (r = 0.404, P = 0.003) in lead-exposed workers. Serum endocan level was an independent risk factor for increased E/E' ratio (ß = 0.704, P = 0.002) and left atrial volume index (ß = 1.158, P = 0.011) and higher level of lead in blood was an independent risk factor for increased E wave (ß = 8.004, P = 0.022) in lead-exposed workers. Conclusion: Worsened diastolic functions may be seen in the course of lead exposure. Due to sharing a similar mechanism, a higher serum level of endocan may be a valuable laboratory clue for impaired diastolic function in this population.

🔖

Cite This Article

KARA, H., KARAKULAK, U. N., GÜNDÜZÖZ, M., BAL, C., ALIŞIK, M., BÜYÜKŞEKERCİ, M., İRİTAŞ, S. B., YILMAZ, Ö. H., TUTKUN, L. (2019). Serum endocan level and diastolic functions in the case of lead exposure. Turkish Journal of Medical Sciences, Cilt: 49 - Sayı: 1, 66–73. https://ajindex.com/articles/114970

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...