Journals / Turkish Journal of Medical Sciences / 2015 / Cilt: 45 - Sayı: 2

What is the main target: a clearer colon with a sennoside-based regime, or adequate bowel cleansing before colonoscopy with a PEG-EL-based regime?

Pages
404–408
Publication Date
2015-08-13
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Conclusion: The best bowel cleansing can be achieved with sennoside-based regimes, whereas a greater proportion of adequate results via colonoscopy were reached with the PEG-EL-based regimes.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Background/aim: Even though polyethylene glycol-electrolyte lavage (PEG-EL)-based regimes have become the gold standard in recent years, to finish drinking 4 L of PEG-EL solution can be difficult.
📊
Key Findings & Data:Materials and methods: Patients over 18 years old undergoing elective colonoscopic procedures between January and March 2011 were included in the study.
💡
Conclusion & Impact:Conclusion: The best bowel cleansing can be achieved with sennoside-based regimes, whereas a greater proportion of adequate results via colonoscopy were reached with the PEG-EL-based regimes.
🔬Design:Research Article
📍Scope:2011 Verileri
⚙️Variables:Precolonoscopic bowel cleansing · polyethylene glycol regime · X-M solution

Abstract

Background/aim: Even though polyethylene glycol-electrolyte lavage (PEG-EL)-based regimes have become the gold standard in recent years, to finish drinking 4 L of PEG-EL solution can be difficult. The quality of sennoside-based bowel-cleansing regimes used in Turkey has been known for some time. Therefore, we aimed to investigate the efficacy of both bowel-cleansing regimes. Materials and methods: Patients over 18 years old undergoing elective colonoscopic procedures between January and March 2011 were included in the study. The patients were divided into 2 groups; in Group 1, 91 patients were given sennoside a + b calcium 500 mg/250 mL (X-M solution, Yenişehir Laboratuarı, Ankara, Turkey), and in Group 2, 94 patients were given 4 L of PEG-EL (Golytely, Boston, MA, USA). Results: The mean age of the patients and the male distribution were similar in the 2 groups. Both inadequate bowel cleansing and the best cleansed bowels were seen in Group 1. The number of inadequate colonoscopies declined when using a whole bowel-cleansing regime from 24.5% to 19.3% in Group 2, but it did not decline in Group 1. Conclusion: The best bowel cleansing can be achieved with sennoside-based regimes, whereas a greater proportion of adequate results via colonoscopy were reached with the PEG-EL-based regimes.

Özet

Background/aim: Even though polyethylene glycol-electrolyte lavage (PEG-EL)-based regimes have become the gold standard in recent years, to finish drinking 4 L of PEG-EL solution can be difficult. The quality of sennoside-based bowel-cleansing regimes used in Turkey has been known for some time. Therefore, we aimed to investigate the efficacy of both bowel-cleansing regimes. Materials and methods: Patients over 18 years old undergoing elective colonoscopic procedures between January and March 2011 were included in the study. The patients were divided into 2 groups; in Group 1, 91 patients were given sennoside a + b calcium 500 mg/250 mL (X-M solution, Yenişehir Laboratuarı, Ankara, Turkey), and in Group 2, 94 patients were given 4 L of PEG-EL (Golytely, Boston, MA, USA). Results: The mean age of the patients and the male distribution were similar in the 2 groups. Both inadequate bowel cleansing and the best cleansed bowels were seen in Group 1. The number of inadequate colonoscopies declined when using a whole bowel-cleansing regime from 24.5% to 19.3% in Group 2, but it did not decline in Group 1. Conclusion: The best bowel cleansing can be achieved with sennoside-based regimes, whereas a greater proportion of adequate results via colonoscopy were reached with the PEG-EL-based regimes.

🔖

Cite This Article

ALTINBAŞ, A., YILMAZ, B., AKTAŞ, B., EKİZ, F., ŞİMŞEK, Z., BAŞAR, Ö., ÇOBAN, Ş., YÜKSEL, O. (2015). What is the main target: a clearer colon with a sennoside-based regime, or adequate bowel cleansing before colonoscopy with a PEG-EL-based regime?. Turkish Journal of Medical Sciences, Cilt: 45 - Sayı: 2, 404–408. https://ajindex.com/articles/114021

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (10)

  1. Froehlich F, Wietlisbach V, Gonvers JJ, Burnand B, Vader JP. Impact of colonic cleansing on quality and diagnostic yield of colonoscopy: the European Panel of Appropriateness of Gastrointestinal Endoscopy European multicenter study. Gastrointest Endosc 2005; 61: 378–384
  2. Thomson A, Naidoo P, Crotty B. Bowel preparation for colonoscopy: a randomized prospective trail comparing sodium phosphate and polyethylene glycol in a predominantly elderly population. J Gastroenterol Hepatol 1996; 11: 103–107
  3. Marshall JB, Pineda JJ, Barthel JS, King PD. Prospective, randomized trial comparing sodium phosphate solution with polyethylene glycol-electrolyte lavage for colonoscopy preparation. Gastrointest Endosc 1993; 39: 631–634
  4. Afridi SA, Barthel JS, King PD, Pineda JJ, Marshall JB. Prospective, randomized trial comparing a new sodium phosphate-bisacodyl regimen with conventional PEG-ES lavage for outpatient colonoscopy preparation. Gastrointest Endosc 1995; 41: 485–489
  5. Lieberman DA, Ghormley J, Flora K. Effect of oral sodium phosphate colon preparation on serum electrolytes in patients with normal serum creatinine. Gastrointest Endosc 1996; 43: 467–469
  6. Poon CM, Lee DW, Mak SK, Ko CW, Chan KC, Chan KW, Sin KS, Chan AC. Two liters of polyethylene glycol-electrolyte lavage solution versus sodium phosphate as bowel cleansing regimen for colonoscopy: a prospective randomized controlled trial. Endoscopy 2002; 34: 560–563
  7. Di Palma JA, Rodriguez R, McGowan J, Cleveland MB. A randomized clinical study evaluating the safety and efficacy of a new, reduced-volume, oral sulfate colon-cleansing preparation for colonoscopy. Am J Gastroenterol 2009; 104: 2275–2284
  8. Abut E, Guveli H, Yasar B, Bolukbas C, Bolukbas FF, Ince AT, Kendir T, Dalay AR, Kurdas OO. Administration of olive oil followed by a low volume of polyethylene glycol-electrolyte lavage solution improves patient satisfaction with right-side colonic cleansing over administration of the conventional volume of polyethylene glycol-electrolyte lavage solution for colonoscopy preparation. Gastrointest Endosc 2009; 70: 515– 521
  9. Ell C, Fischbach W, Bronisch HJ, Dertinger S, Layer P, Rünzi M, Schneider T, Kachel G, Grüger J, Köllinger M et al. Randomized trial of low-volume PEG solution versus standard PEG + electrolytes for bowel cleansing before colonoscopy. Am J Gastroenterol 2008; 103: 883–893
  10. El Sayed AM, Kanafani ZA, Mourad FH, Soweid AM, Barada KA, Adorian CS, Nasreddine WA, Sharara AI. A