Journals / Turkish Journal of Medical Sciences / 2019 / Cilt: 49 - Sayı: 3

Diagnostic value of 3D power Doppler ultrasound in the characterization of thyroid nodules

Pages
723–729
Publication Date
2019-06-01
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Vascular indices in malignant nodules were significantly higher than those in benign nodules (P

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Background/aim: This study aimed to evaluate the diagnostic value of vascular indices obtained using 3D power Doppler ultrasound (3D PDUS) in differentiation of benign and malignant thyroid nodules.Materials and methods: Sixty-seven patients (56 female, 11 male, mean age 44.6) with 81 thyroid nodules exhibiting mixed (peripheral and central) vascularization patterns, with the largest diameter between 10 and 30 mm, were prospectively evaluated using 3D PDUS.
📊
Key Findings & Data:The optimum cutoff values for the differentiation of benign and malignant nodules were identified, and diagnostic efficacy was calculated using receiver operating characteristic (ROC) analysis.Results: Fifty-six of the 81 nodules included in this study were diagnosed as benign and 25 as malignant.
💡
Conclusion & Impact:Vascular indices in malignant nodules were significantly higher than those in benign nodules (P
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Thyroid nodules · three-dimensional power Doppler ultrasound · vascular indices

Abstract

Background/aim: This study aimed to evaluate the diagnostic value of vascular indices obtained using 3D power Doppler ultrasound (3D PDUS) in differentiation of benign and malignant thyroid nodules.Materials and methods: Sixty-seven patients (56 female, 11 male, mean age 44.6) with 81 thyroid nodules exhibiting mixed (peripheral and central) vascularization patterns, with the largest diameter between 10 and 30 mm, were prospectively evaluated using 3D PDUS. Nodule volume, vascularization index (VI), flow index (FI), and vascularization flow index (VFI) were calculated using the Virtual Organ Computer-aided Analysis (VOCAL) software, and these indices were then compared with regard to the cytohistopathology-based diagnosis. The optimum cutoff values for the differentiation of benign and malignant nodules were identified, and diagnostic efficacy was calculated using receiver operating characteristic (ROC) analysis.Results: Fifty-six of the 81 nodules included in this study were diagnosed as benign and 25 as malignant. Vascular indices in malignant nodules were significantly higher than those in benign nodules (P

🔖

Cite This Article

CANSU, A., AYAN, E., KUL, S., EYÜBOGLU, İ., OĞUZ, Ş., MUNGAN, S. (2019). Diagnostic value of 3D power Doppler ultrasound in the characterization of thyroid nodules. Turkish Journal of Medical Sciences, Cilt: 49 - Sayı: 3, 723–729. https://ajindex.com/articles/113962