Journals / Turkish Journal of Medical Sciences / 2018 / Cilt: 48 - Sayı: 2

Peritoneal dialysis in neonates: six years of single center experience

Pages
231–236
Publication Date
2018-04-01
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

A trocar catheter appears safe even in premature babies, and closed three-way stopcock system seems to be reliable at the bedside in NICUs.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Background/aim: Peritoneal dialysis (PD) is generally considered the practical dialysis modality for neonates in the treatment of acute kidney injury (AKI) and metabolic disturbances. e aim of this study was to evaluate the indications, complications, and outcomes of PD between January 2011 and December 2016.
📊
Key Findings & Data:Materials and methods: This study included all 56 neonates that underwent PD over six years in our neonatal intensive care unit (NICU).
💡
Conclusion & Impact:A trocar catheter appears safe even in premature babies, and closed three-way stopcock system seems to be reliable at the bedside in NICUs.
🔬Design:Review & Systematic Survey
📍Scope:2011 Verileri
⚙️Variables:Neonates · peritoneal dialysis · trocar catheter

Abstract

Background/aim: Peritoneal dialysis (PD) is generally considered the practical dialysis modality for neonates in the treatment of acute kidney injury (AKI) and metabolic disturbances. e aim of this study was to evaluate the indications, complications, and outcomes of PD between January 2011 and December 2016. Materials and methods: This study included all 56 neonates that underwent PD over six years in our neonatal intensive care unit (NICU). A retrospective chart review was performed for all patients in our institution. Results: The incidence of PD was 1.32% (56/4230 patients) during this period. Mean birth weight of the patients was 2267.77 ± 1060.63 (540?5050) g. irty-four (60.7%) patients were premature. Fourteen patients (25%) were in the postoperative period of cardiac surgery due to congenital cardiac defects, fourteen patients (25%) were diagnosed with metabolic diseases, one patient had hypoxic ischemic encephalopathy, and another patient had severe pulmonary hypertension. Conclusion: In the acute setting of a neonatal intensive care unit, PD performed in a neonate provides a technically simple method of steady uid, solute removal, and correction of electrolyte abnormalities. A trocar catheter appears safe even in premature babies, and closed three-way stopcock system seems to be reliable at the bedside in NICUs.

🔖

Cite This Article

ÖZLÜ, F., YILDIZDAŞ, H. Y., ŞEKER, G., ŞİMŞEK, H., BAYAZIT, A. K., SATAR, M. (2018). Peritoneal dialysis in neonates: six years of single center experience. Turkish Journal of Medical Sciences, Cilt: 48 - Sayı: 2, 231–236. https://ajindex.com/articles/113666