Journals / Turkish Journal of Medical Sciences / 2016 / Cilt: 46 - Sayı: 5

The effect of pneumoperitoneum on intravascular fibrinolytic activity in rats

Pages
1528–1533
Publication Date
2016-10-01
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Conclusion: Pneumoperitoneum of the coagulation system can be changed by duration of time and pressure.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Background/aim: Venous stasis during pneumoperitoneum in laparoscopic surgery is closely related to fibrin synthesis and deposition.
📊
Key Findings & Data:Materials and methods: After the pneumoperitoneum model was established in rats, PAI-1, tPA, TAFI, D-dimer, and fibrinogen activities were evaluated in different time periods under different pressures in groups including 6 rats.
💡
Conclusion & Impact:Conclusion: Pneumoperitoneum of the coagulation system can be changed by duration of time and pressure.
🔬Design:Modeling & Simulation
📍Scope:Comprehensive Sample
⚙️Variables:Pneumoperitoneum · fibrinolysis · hypercoagulability

Abstract

Background/aim: Venous stasis during pneumoperitoneum in laparoscopic surgery is closely related to fibrin synthesis and deposition. The etiologic factors underlying fibrinolysis or hypercoagulability are not clearly defined. This study aimed to determine the effects of pneumoperitoneum time and pressure on coagulation cascade and the fibrinolytic pathway. Materials and methods: After the pneumoperitoneum model was established in rats, PAI-1, tPA, TAFI, D-dimer, and fibrinogen activities were evaluated in different time periods under different pressures in groups including 6 rats. Group 1 did not undergo any procedure. Group 2 received 8 mmHg of pressure for 30 min, Group III 8 mmHg for 60 min, Group IV 12 mmHg for 30 min, and Group V 12 mmHg for 60 min. Results: D-dimer levels had a tendency to decrease with increasing intraabdominal pressures. In both low and high pressure groups, fibrinogen had a tendency to increase with exposure time. There was no statistically significant difference among the study groups in terms of fibrinogen, D-dimer, and PAI-1. The levels of TAFI were significantly decreased with increasing pressure regardless of the exposure time. Conclusion: Pneumoperitoneum of the coagulation system can be changed by duration of time and pressure.

🔖

Cite This Article

DİKMEN, K., DİKMEN, A. U., BOSTANCI, H., KARAMERCAN, A., YAĞCI, A. M., AKIN, M., AYTAÇ, B. (2016). The effect of pneumoperitoneum on intravascular fibrinolytic activity in rats. Turkish Journal of Medical Sciences, Cilt: 46 - Sayı: 5, 1528–1533. https://ajindex.com/articles/113640

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...