Journals / Turkish Journal of Medical Sciences / 2020 / Cilt: 50 - Sayı: 2

Evaluation of major complications associated with percutaneous CT-guided biopsy of lung nodules below 3 cm

Pages
369–374
Publication Date
2020-03-01
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

At regression analysis, for parenchymal haemorrhage, lesion depth P

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Background/aim: The aim of this study was to evaluate retrospectively the incidence and risk factors for the serious complications of pneumothorax and/or parenchymal haemorrhage occurring after computed tomography CT guided transthoracic biopsy.
📊
Key Findings & Data:Results: Between 2016 and 2017, 309 cases with lesions below 3 cm in diameter of a total of 768 40.2% CT-guided chest biopsy patients were selected for retrospective review.
💡
Conclusion & Impact:At regression analysis, for parenchymal haemorrhage, lesion depth P
🔬Design:Review & Systematic Survey
📍Scope:2016 Verileri
⚙️Variables:Lung · biopsy · radiology

Abstract

Background/aim: The aim of this study was to evaluate retrospectively the incidence and risk factors for the serious complications of pneumothorax and/or parenchymal haemorrhage occurring after computed tomography CT guided transthoracic biopsy. Materials and methods: The relation between the incidence of pneumothorax and parenchymal haemorrhage due to biopsy, age, sex, lesion localization, lesion size, duration of the procedure, depth of lesion, number of pleural insertions of the biopsy needle and pathology results were statistically evaluated. Results: Between 2016 and 2017, 309 cases with lesions below 3 cm in diameter of a total of 768 40.2% CT-guided chest biopsy patients were selected for retrospective review. The rate of pneumothorax and parenchymal haemorrhage was 18.1% 59/309 and 51% 158/309 , respectively post biopsy. The number of needle pleural insertions was correlated with the development of pneumothorax P = 0.002 . At regression analysis, for parenchymal haemorrhage, lesion depth P

🔖

Cite This Article

ÇAKIR, Ö., ÇAM, İ., KOÇ, U., ÇİFTÇİ, E. (2020). Evaluation of major complications associated with percutaneous CT-guided biopsy of lung nodules below 3 cm. Turkish Journal of Medical Sciences, Cilt: 50 - Sayı: 2, 369–374. https://ajindex.com/articles/113402

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (13)

  1. Gould MK, Ananth L, Barnett PG. A clinical model to estimate the pretest probability of lung cancer in patients with solitary pulmonary nodules. Chest 2007
  2. doi: 10.1378/ chest.06-1261 2. Haaga JR, Alfidi RJ. Precise biopsy localization by computer tomography. Radiology 1976
  3. doi: 10.1148/118.3.603 3. McNulty W, Cox G, Au Yong I. Investigating the solitary pulmonary nodule. British Medical Journal 2012
  4. e2759. doi: 10.1136/bmj. e2759. 4. Xu C, Hao K, Song Y, Yu L, Hou Z et al. Early diagnosis of solitary pulmonary nodules. Journal of Thoracic Disease 2013
  5. doi: 10.3978/j.issn.2072-1439.2013.11.19 5. Baysal T, Mızrak B, Soysal Ö, Sığırcı A, Kutlu R. The role of immediate cytological evaluation in CT-guided fine needle aspiration biopsies of the thorax. Diagnostic and Interventional Radiology 2002
  6. doi: 10.1016/S0009-9260(05)82930- 7 6. Soubani AO. The evaluation and management of the solitary pulmonary nodule. Postgraduate Medical Journal. 2008
  7. doi: 10.1136/pgmj.2007.063545 7. Heerink WJ, de Bock GH, de Jonge GJ, Groen HJ, Vliegenthart R et al. Complication rates of CT-guided transthoracic lung biopsy: meta-analysis. European Radiology 2017
  8. doi: 10.1007/s00330-016-4357-8 8. Sinner WN. Complications of percutaneous transthoracic needle aspiration biopsy. Acta Radiologica 1976
  9. 17 (6): 813-828. 9. Graham RJ, Heyd RL, Raval VA, Barrett TF. Lung torsion after percutaneous needle biopsy of lung. American Journal of Roentgenology. 1992
  10. 159 (1): 35-37. doi: 10.2214/ ajr.159.1.1609717 10. Perlmutt LM, Johnston WW, Dunnick NR. Percutaneous transthoracic needle aspiration: a review. American Journal of Roentgenology 1989
  11. 152 (3): 451-455. doi: 10.2214/ajr.152.3.451 11. Chansky K, Detterbeck FC, Nicholson AG, Rusch VW, Vallières E et al. The IASLC lung cancer staging project: external validation of the revision of the TNM stage groupings in the eighth edition of the TNM classification of lung cancer. Journal of Thoracic Oncology 2017
  12. 12 (7): 1109-1121. doi: 10.1016/j. jtho.2017.01.011 12. Laurent F, Latrabe V, Vergier B, Montaudon M, Vernejoux JM et al. CT-guided transthoracic needle biopsy of pulmonary nodules smaller than 20 mm: results with an automated 20-gauge coaxial cutting needle. Clinical Radiology 2000
  13. 55 (4): 281-287. doi: 10.1053/crad.1999.0368 13. Geraghty PR, Kee ST, McFarlane G, Razavi MK, Sze DY et al. CT-guided transthoracic needle aspiration biopsy of pulmonar