Journals / Turkish Journal of Medical Sciences / 2019 / Cilt: 49 - Sayı: 5

Shear wave versus strain elastography in the differentiation of benign and malignant breast lesions

Pages
1509–1517
Publication Date
2019-10-01
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Selecting a cutoff SR value of 3.22 led to an 88.1% sensitivity and an 88.4% specificity (AUC: 0.913 [95% CI: 0.854?0.971], P

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Background/aim: To evaluate and compare the diagnostic performances of shear wave elastography (SWE) and strain elastography (SE) in the differentiation of benign and malignant breast lesions.Materials and methods: The current study included 87 breast lesions in 84 patients.
📊
Key Findings & Data:Receiver operating characteristic (ROC) curves were constructed to assess and compare the diagnostic performances of each parameter.
💡
Conclusion & Impact:Selecting a cutoff SR value of 3.22 led to an 88.1% sensitivity and an 88.4% specificity (AUC: 0.913 [95% CI: 0.854?0.971], P
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Breast · diagnostic performance · shear wave elastography

Abstract

Background/aim: To evaluate and compare the diagnostic performances of shear wave elastography (SWE) and strain elastography (SE) in the differentiation of benign and malignant breast lesions.Materials and methods: The current study included 87 breast lesions in 84 patients. The Breast Imaging Reporting and Data System (BIRADS) categories were determined with ultrasound features. The maximum shear wave velocity (SWV), mean SWV, maximum SWV to fat SWV ratio, and mean SWV to fat SWV ratio were measured using SWE. The strain ratio (SR) was calculated as the ratio of lesion strain to the adjacent fat strain using SE. Receiver operating characteristic (ROC) curves were constructed to assess and compare the diagnostic performances of each parameter. Results: Forty-five benign and 42 malignant lesions were diagnosed. The sensitivity and specificity of the BIRADS classification was 100% and 35.6%, respectively. Selecting a cutoff SR value of 3.22 led to an 88.1% sensitivity and an 88.4% specificity (AUC: 0.913 [95% CI: 0.854?0.971], P

🔖

Cite This Article

GÜRÜF, A., ÖZTÜRK, M., BAYRAK, İ. K., POLAT, A. V. (2019). Shear wave versus strain elastography in the differentiation of benign and malignant breast lesions. Turkish Journal of Medical Sciences, Cilt: 49 - Sayı: 5, 1509–1517. https://ajindex.com/articles/113388

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...