Journals / Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi / 2026 / Cilt: 32 Sayı: 4

Design and implementation of a portable device for visual field testing

Görme alanı testi için taşınabilir bir cihaz tasarımı ve uygulaması

Kerim Özkara(KARABUK UNIVERSITY)
Aeshah Basim Younus Al-Bayatı(KARABUK UNIVERSITY)
Ahmet Reşit Kavsaoğlu(KARABUK UNIVERSITY)
Pages
707–717
Publication Date
2026-01-06
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

This study offers a cost-effective, user-friendly, and portable alternative to traditional visual field-testing devices for potential clinical diagnosis and patient education applications.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Inspired by the Humphrey Field Analyzer (HFA) device used in the diagnosis and monitoring of diseases such as glaucoma that cause vision loss, this study developed a low-cost, portable device application that is integrated with existing devices and has a design that facilitates patient use.
📊
Key Findings & Data:The mechanical design includes a visual stimulus box integrated with a special chin rest to ensure user ergonomics and reliable results.
💡
Conclusion & Impact:This study offers a cost-effective, user-friendly, and portable alternative to traditional visual field-testing devices for potential clinical diagnosis and patient education applications.
🔬Design:Araştırma Makalesi
📍Scope:Comprehensive Sample
⚙️Variables:Görme alanı testi · Glokom Tanısı · Düşük Maliyetli Tıbbi Cihaz

Abstract

Inspired by the Humphrey Field Analyzer (HFA) device used in the diagnosis and monitoring of diseases such as glaucoma that cause vision loss, this study developed a low-cost, portable device application that is integrated with existing devices and has a design that facilitates patient use. The system design consists of mechanical, hardware, and software components. The mechanical design includes a visual stimulus box integrated with a special chin rest to ensure user ergonomics and reliable results. The hardware component features an LED-based visual stimulus circuit designed in a 24/2 pattern and controlled by an Arduino Mega microcontroller. The functionality of the hardware has been verified using Proteus simulation software. On the software side, a user interface has been developed using MATLAB Appdesigner, which enables two-way communication with the Arduino Mega microcontroller via a serial port. The developed visual field-testing system is a low-cost, easy-to-install, portable, and reliable system that does not require specialized technical personnel. Compared to commercial devices, the design eliminates motor noise associated with stimulus projection in HFA devices, making it quieter and less distracting for users. This study offers a cost-effective, user-friendly, and portable alternative to traditional visual field-testing devices for potential clinical diagnosis and patient education applications.

Özet

Görme alanı kaybına neden olan glokom gibi hastalıkların teşhisi ve takibinde kullanılan Humphrey Alan Analizörü’nden (HFA) esinlenilen makale çalışmasında mevcut cihazlara uyum sağlayan ve hasta kullanımını kolaylaştıran tasarım ile düşük maliyetli ve taşınabilir bir cihaz uygulaması geliştirilmiştir. Sistem tasarımı mekanik, donanım ve yazılım bileşenlerinden oluşmaktadır. Mekanik tasarım, kullanıcı ergonomisini ve güvenilir sonuçları sağlamak için özel bir çene desteği ile entegre edilmiş bir görsel uyaran kutusu içerir. Donanım bileşeni, bir Arduino Mega mikrodenetleyici tarafından kontrol edilen 24/2 deseninde tasarlanmış LED tabanlı bir görsel uyaran devresine sahiptir. Donanımın işlevselliği Proteus simülasyon yazılımı kullanılarak doğrulanmıştır. Yazılım tarafında, seri port üzerinden Arduino Mega mikrodenetleyici ile çift yönlü iletişime olanak sağlayan MATLAB Appdesigner kullanılarak bir kullanıcı arayüzü geliştirilmiştir. Geliştirilen görme alanı test sistemi, uzman teknik personel gerektirmeyen, düşük maliyetli, kurulumu kolay, taşınabilir ve güvenilir bir sistemdir. Tasarım ticari cihazlarla karşılaştırıldığında, HFA cihazlarındaki uyaran projeksiyonuyla ilişkili motor gürültülerini ortadan kaldırarak sessiz çalışmasıyla kullanıcılar için daha az dikkat dağıtıcı hale gelmektedir. Bu çalışma, potansiyel klinik tanı ve hasta eğitimi uygulamalarıyla, geleneksel görme alanı test cihazlarına uygun maliyetli, kullanıcı dostu ve taşınabilir bir alternatif sunmaktadır.

🔖

Cite This Article

Özkara, K., Al-Bayatı, A. B. Y., Kavsaoğlu, A. R. (2026). Design and implementation of a portable device for visual field testing. Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi, Cilt: 32 Sayı: 4, 707–717. https://doi.org/10.65206/pajes.98444

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (33)

  1. Racette L, Fischer M, Bebie H, Holló G, Johnson CA, Matsumoto C. Visual Field Digest: A Guide to Perimetry and the Octopus Perimeter. 8th ed. Köniz, Switzerland, Haag Streit AG, 2019.
  2. Yalvaç I. “Glokomda Humphrey Görme Alanı.” https://www.todnet.org/glokom/Humphrey.htm (03.01.2024).
  3. Bülbül E. Visual Field Testing Using Forecasting And Virtual Reality. MSc Thesis, Middle East Technical University, Ankara, Türkiye, 2022.
  4. Ichhpujani P, Thakur S, Sahi R. K, & Kumar S. “Validating tablet perimetry against standard Humphrey Visual Field Analyzer for glaucoma screening in Indian population”. Indian Journal of Ophthalmology, 69(1), 87-91, 2021.
  5. Tsapakis S, Papaconstantinou D, Diagourtas A, Droutasas K, Andreanos K, Moschos MM, Brouzas D. “Visual field examination method using virtual reality glasses compared with the Humphrey perimeter”. Clinical Ophthalmology, 11, 1431-1443, 2017.
  6. Selvaraj D. Using Google Cardboard to perform a visual field screening test. MSc Thesis, Iowa State University. Ames, Iowa. 2018.
  7. Johnson CA, Thapa S, Kong, YXG, Robin AL. “Performance of an iPad application to detect moderate and advanced visual field loss in Nepal”. American Journal of Ophthalmology, 182, 147–154, 2017.
  8. Shetty V, Sankhe P, Haldipurkar SS, Haldipurkar T, Dhamankar R, Kashelkar P, Shah D, Mhatre P, Setia MS. “Diagnostic performance of the PalmScan VF2000 virtual reality visual field analyzer for identification and classification of glaucoma”. Journal of Ophthalmic & Vision Research, 17(1), 33-41, 2022.
  9. Mees L, Upadhyaya S, Kumar P, Kotawala S, Haran S, Rajasekar S, Friedman DS, Venkatesh R. “Validation of a head-mounted virtual reality visual field screening device”. Journal of Glaucoma, 29(2), 86–91, 2020.
  10. Prechtl TechSolutions. “Perimeter PANO”. https://www.prechtl-techsolutions.com/perimeter-pano (07.05.2024).
  11. El-Khoury S, Hannen T, Dragnea DC, Ngounou F, Preußner PR. “Pattern noise (PANO): A new automated functional glaucoma test”. International Ophthalmology, 38, 1993–2003, 2018.
  12. Hannen T, El-Khoury S, Patel R, Ngounou F, Preußner PR. “Comparison of the automated pattern–noise (PANO) glaucoma test with the HFA, an FDT stimulus, and the fundus area cup-to-disk ratio”. Journal of Current Glaucoma Practice, 15(3), 132-138, 2021.
  13. Chen Z. Deep Learning for Glaucoma Diagnosis and Monitoring and for Video Processing. PhD Thesis, New York University Tandon School of Engineering, New York, USA, 2024.
  14. Sebastian ET. The Complexity and Origins of the Human Eye: A Brief Study on the Anatomy, Physiology, and Origin of the Eye. Senior Thesis, Honors Program, Liberty University, Virginia, USA. 2010.
  15. American Academy of Ophthalmology. “Retina”. https://www.aao.org/eye-health/anatomy/retina-103 (11.07.2024).
  16. Hanes E. “The anatomy of the retina. Verywell Health.” https://www.verywellhealth.com/retina-anatomy-4800793 (11.07.2024).
  17. Kolb H. “Simple anatomy of the retina. WEBVISION The Organization of the Retina and Visual System”. https://webvision.med.utah.edu/book/part-i-foundations/simple-anatomy-of-the-retina/ (11.07.2024).
  18. Friedman DS, Wolfs RC, O'Colmain BJ, Klein BE, Taylor HR, West S, Leske MC, Mitchell P, Congdon N, Kempen J. “Prevalence of open-angle glaucoma among adults in the United States”. Archives of Ophthalmology, 122(4), 532-538, 2004.
  19. Kummet C. Statistical Modeling to İmprove the Detection of Glaucoma Progression. PhD Thesis, The University of Iowa, Iowa City, Iowa. 2013.
  20. ZEISS Medical Technology. “ZEISS Humphrey Perimeters”. https://www.zeiss.com/meditec/en/products/perimetry.html (20.05.2024).
  21. MedicalPriceOnline. “HUMPHREY 750 Field Analyzer”. https://www.medicalpriceonline.com/medical-equipment/humphrey/humphrey-750-field-analyzer/ (01.08.2024).
  22. OphthalmicMart. “Zeiss Humphrey Field Analyzer 3 Visual Field-Testing System”. https://www.ophthalmicmart.com/product/humphrey-field-analyzer-3/ (01.08.2024).
  23. Nava Ophthalmic. “Carl Zeiss Humphrey Field Analyzer 3 (HFA3)”. https://navaophthalmic.com/product/zeiss-hfa3/ (01.08.2024).
  24. Webeye Ophthalmology Archive. “1990 Perimetry Standards”. https://web.archive.org/web/20180703025201/http://webeye.ophth.uiowa.edu/ips/GEN-INFO/standards/IPS90.HTM (03.01.2024).
  25. Greve EL. Single and Multiple Stimulus Static Perimetry in Glaucoma; The two Phases of Perimetry. 1st ed. Dordrecht, Netherlands, Springer, 1973.
  26. Arduino Documentation. “Secrets of Arduino PWM”. https://docs.arduino.cc/tutorials/generic/secrets-of-arduino-pwm/ (19.06.2024).
  27. Arduino Forum. “Code for PWM Signals to H bridge” https://forum.arduino.cc/t/code-for-pwm-signals-to-h-bridge/6474 (19.06.2024).
  28. Walsh TJ. Visual Fields Examination and Interpretatio.3rd ed. USA, Oxford University Press, 2011.
  29. Appasamy Associates Empowering Vision. “Appa Auto Perimeter AP901 CTS Glaufield Lite Swap”. https://www.appasamy.com/ophthalmology-optometry/glaufield-lite-swap (08.05.2024).
  30. Tas MO, Yavuz HS. "A human-computer interaction system based on eye, eyebrow and head movements". Pamukkale University Journal of Engineering Sciences, 28(5), 632-642, 2022.
  31. Aygün AB. Kavsaoglu AR. “An innovative P300 speller brain–computer interface design: Easy screen”. Biomedical Signal Processing and Control, 75, 103593, 2022.
  32. Küçükakarsu M, Kavsaoğlu AR, Alenezi F, Alhudhaif A, Alwadie R, Polat K. “A novel automatic audiometric system design based on machine learning methods using the brain’s electrical activity signals”. Diagnostics, 13(3), 575, 2023.
  33. Nazli B, Kavsaoğlu AR. “Brain-Computer interfaces with auditory stimuli: A review study”. Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi, 31(4), 633–647,2025.