Journals / Electrica / 2013 / Cilt: 13 Sayı: 2

DESIGN OF A BASIC PIEZORESISTIVE MICROCANTILEVER BIOSENSOR

Journal
Electrica
Pages
1641–1645
Publication Date
2013-12-25
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Additionally, effects of different shaped holes upon sensor are studied.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Microcantilevers are one of the basic micromechanical structures.
📊
Key Findings & Data:They are fixed at one ends and the other ends can move freely like a diving board.
💡
Conclusion & Impact:Additionally, effects of different shaped holes upon sensor are studied.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Microcantilever · piezoresistive detection · biosensor.

Abstract

Microcantilevers are one of the basic micromechanical structures. They are fixed at one ends and the other ends can move freely like a diving board. Their sizes are in the micrometer and nanometer ranges. Microcantilevers are called microcantilever sensors when their surfaces are functionalized to detect specific molecules. Since these sensors have offered remarkable possibilities in detection, they have been used in many fields such as clinical diagnosis, drug screening and pathogen detection. In the microcantilever sensors, various detection methods are available such as piezoresistive, optical, capacitive and piezoelectric. Each sensing method holds own advantages and disadvantages. By the advantage of allowing integration of the read-out electronics on the same chip, piezoresistive detection becomes prominent. So piezoresistive detection is chosen in this work and a basic piezoresistive microcantilever biosensor design is introduced. Furthermore, by making geometrical alterations on microcantilever and piezoresistive layer, effects of these variations upon sensitivity, vertical displacement and change in resistance are investigated. Additionally, effects of different shaped holes upon sensor are studied.

🔖

Cite This Article

Sacu, İ., Alcı, M. (2013). DESIGN OF A BASIC PIEZORESISTIVE MICROCANTILEVER BIOSENSOR. Electrica, Cilt: 13 Sayı: 2, 1641–1645. https://ajindex.com/articles/1017479

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (12)

  1. Hansen, K. M., Thundat, T., “Microcantilever biosensors”, Methods, Vol: 37, No: 1, pp. 57-64, 2005.
  2. Frometa, N. R., “Cantilever biosensors”, Biotecnologia Aplicada, Vol: 23, No: 4, pp. 320-323, 2006.
  3. Bais, B., Rahim, R. A., Majlis, B. Y., “Finite element and system level analyses of piezoresistive microcantilever for biosensing applications”, Australian Journal of Basic & Applied Sciences, Vol: 5, No: 12, pp. 1038-1046, 20 Lim, Y. C., Kouzani, A. Z., Duan, W., Kaynak, A., “Effects of design parameters on sensivity of microcantiilever biosensors”, IEEE International Conference on Complex Medical Engineering-ICME, 2010.
  4. Alvarez, M., Lechuga, L. M., “Microcantilever-based platforms as biosensing tools”, Analyst, Vol: 135, No: 5, pp. 827-836, 2010.
  5. Ziegler, C., “Cantilever based biosensors”, Analytical & Bioanalytical Chemistry. Vol: 379, No: 7/8, pp. 946-959, 200 Villanueva, G., Rius, G., Montserrat, J., Murano, F. P., Bausells, J., “Piezoresistive microcantilevers for biomolecular force detection”, SCED, Spanish Conference on Electron Devices IEEE, 2007.
  6. He, J. H., Li, Y. F., ”High sensivity piezoresistive cantilever sensor for biomolecular detection”, Journal of Physics: Conference Series, Vol: 34, pp. 429-435, 2006.
  7. Johnson, B. N., Mutharasan, R., “Biosensing using dynamic - mode cantilever sensors: A review”, Biosensors and Bioelectronics, Vol: 32, No: 1, pp. 1-18, 2011.
  8. Datar, R., Kim, S., Jeon, S., Hesketh, P., Manalis, S., Boisen, A., Thundat, T., “Cantilever sensors: Nanomechanical tools for diagnostics”, MRS Bulletin, Vol: 34, No: 6, pp449-454, 2009.
  9. Mutyala, M. S. K., Bandhanadham, D., Pan, L., Pendyala, V. R., Ji, H. F., “Mechanical and electronic approaches to improve the sensivity of microcantilever sensors”, Acta Mech Sin, Vol: 25, No: 1, pp. 1-12, 2009.
  10. Yang, M., Zhang, X., Vafai, K., Ozkan, C. S., “High sensitivity piezoresistive cantilever design and optimization for analyte-receptor binding”, Journal of Micromechanics and Microengineering, Vol: 13, No: 6, pp. 864-872, 200 Kale, N. S., Nag, S., Pinto, R., Rao, V. R., “Fabrication and characterization of a polymeric microcantilever with an encapsulated hotwire cvd polysilicon piezoresitor”, Journal of Microelectromechanical Systems, Vol: 18, No:1, pp. 7987, 2009.
  11. Park, S. J., Doll, J. C., Pruitt, B., “Piezoresistive cantilever performance - part 1: Analytical model for sensivity”, Journal of Microelectromechanical Systems, Vol: 19, No:1, pp. 137-148, 2010.
  12. Thilagar, S. H., Kalairasi, A. R.