PERFORMANCE ANALYSIS OF DOUBLE REHEAT TURBINE IN MULTI -AREA AGC SYSTEM USING CONVENTIONAL AND ANT COLONY OPTIMIZATION TECHNIQUE

Journal
Electrica
Pages
1849–1854
Publication Date
2015-11-16
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Simulation result shows that contribution of AGC with AI PID controller more superior to conventional controller.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:The responsibility of power system is to ensure that adequate power generation with good quality and more economic power delivery to all consumers.
📊
Key Findings & Data:Hence, proper control strategy is required to maintain a continuous power balance between power generation and surplus.
💡
Conclusion & Impact:Simulation result shows that contribution of AGC with AI PID controller more superior to conventional controller.
🔬Design:Modeling & Simulation
📍Scope:Comprehensive Sample
⚙️Variables:Automatic Generation contro · Cost function · Doule reheat turbine

Abstract

The responsibility of power system is to ensure that adequate power generation with good quality and more economic power delivery to all consumers. Hence, proper control strategy is required to maintain a continuous power balance between power generation and surplus. So it is necessary to implement Automatic Generation control for more efficient control performance. In this paper , three area reheat thermal power is considered for the investigation and each generating unit equipped with either Single Reheat Turbine (SRT) or Double Reheat Turbine (DRH) with Proportional-Integral-Derivative(PID) controller. Optimal controller gain values are obtained using both conventional and Artificial Intelligence (AI) optimization technique. Finally, performances of AI-PID controller are compared with conventional optimized PID controller. Simulation result shows that contribution of AGC with AI PID controller more superior to conventional controller.

🔖

Cite This Article

KALİANNAN, J., BASKARAN, A. (2015). PERFORMANCE ANALYSIS OF DOUBLE REHEAT TURBINE IN MULTI -AREA AGC SYSTEM USING CONVENTIONAL AND ANT COLONY OPTIMIZATION TECHNIQUE. Electrica, Cilt: 15 Sayı: 1, 1849–1854. https://ajindex.com/articles/1017445

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (8)

  1. S.Banerjee, J.K.Chatterjee, S.C.Tripathy, “Application of magnetic energy storage unit as load-frequency stabilizer,” IEEE transactions on energy conversion, Vol. 5, pp. 46-51, 1990. S.C.Tripathy,R.Balasubramanian, P.S.Chandramohanan Nair “Small rating capacitive energy storage for dynamic performance improvement of automatic generation control,” IEE proceedings-C, vol.138, pp.1.3-111,1991.
  2. I.A.Chidambaram, B.Paramasivam, “Genetic algorithm based decentralized controllerfor load-frequency control of interconnected power systems with RFB considering TCPS in the tie-line,” International journal of electronic engineering research, Vol. 1, pp.299-312,2009. J.B.X.Devota,M.G.Rabbani, S.Elangovan, “Effects of SMES unit on AGC dynamcs,” Department of electrical engineering, National university of singapore IEEE catlouge No.98EX137,pp.61-661998. S.K.Aditya,D.Das, “Battery energy storage for load frequency control of an interconnected power system,” Electric power system research, Vol.58, pp.179- 185,2001.
  3. B.Paramasivam, I,A,Chidambaram, “Bacterial foraging optimization load based frequency control of interconnected power systems with static synchronous series compensator,” International journal of latesttrends in computing,Vol.1,pp.7-13,2010.
  4. Ravi Shankar, Kalyan Chatterjee, T.K.Chartterjee, “FACTS controller hydrothermal power system,” International journal of engineering science and technology, Vol.4,pp.1776- 1786,2012. for interconnected H.Shayeghi, H.A.Shayanfar,A.Jalili, “LFC design of a deregulated power system with TCPS using PSO,” world academy of science, engineering and technology, Vol.28,pp.570-578,2009.
  5. Paramasivam Balasundaram, Chidambaram Iangi Akilandam, “ ABC algorithm based load-frequency controller for an interconnected power system considering nonlinearities and coordinated with UPFC and RFB,” International journal of engineering and Innovative technology, Vol.1, pp.1-11, 2012.
  6. Tetsuo Sasaki, Toshihisa Kadoya, Kazuhiro Enomoto, “ Study on load frequency control using Redox flow batteries,” IEEE transactions on power systems, Vol.19, pp.660-667,2004.
  7. K.Jagatheesan, B.Anand, “Dynamic Performance of Multi-Area Hydro Thermal Power Systems with Integral Controller considering various performance Indices methods,” Proceedings of the IEEE International conference of Emerging trends in Science, Engineering and Technology (INCOSET), 2012, pp.474-478.
  8. B.Anand, Ebenezer Jeyakumar.A., “Load Frequency control with Fuzzy logic Controller considering Non- Linea