Journals / Electrica / 2016 / Cilt: 16 Sayı: 2

Electrostatic Analysis of a Short Accident in Cable Trays for Intelligent Pressure Transmitters

Journal
Electrica
Pages
2039–2045
Publication Date
2016-09-23
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

After obtaining the modal coefficients from Dirichlet and Neumann boundary conditions, we then derive distributions of potential and electric field, capacitance matrix, effecive didlectric constant, and characteristic impedance to evaluate the electromagnetic influence caused by a short accident in the enclosed-cable tray.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:We apply the mode-matching method to the electrostatic analysis of shorted enclosed-cable trays that are generally used in industrial facilities such as a nuclear power plant.
📊
Key Findings & Data:In mode-matching formulation on potential distribution, we utilize Laplace’s equation and superposition principle.
💡
Conclusion & Impact:After obtaining the modal coefficients from Dirichlet and Neumann boundary conditions, we then derive distributions of potential and electric field, capacitance matrix, effecive didlectric constant, and characteristic impedance to evaluate the electromagnetic influence caused by a short accident in the enclosed-cable tray.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Enclosed-cable tray · mode-matching method · electromagnetic influence

Abstract

We apply the mode-matching method to the electrostatic analysis of shorted enclosed-cable trays that are generally used in industrial facilities such as a nuclear power plant. In mode-matching formulation on potential distribution, we utilize Laplace’s equation and superposition principle. After obtaining the modal coefficients from Dirichlet and Neumann boundary conditions, we then derive distributions of potential and electric field, capacitance matrix, effecive didlectric constant, and characteristic impedance to evaluate the electromagnetic influence caused by a short accident in the enclosed-cable tray.

🔖

Cite This Article

CHOO, J., KİM, H. T., PARK, H. S., JEONG, C. H. (2016). Electrostatic Analysis of a Short Accident in Cable Trays for Intelligent Pressure Transmitters. Electrica, Cilt: 16 Sayı: 2, 2039–2045. https://ajindex.com/articles/1017422

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...