Journals / Electrica / 2017 / Cilt: 17 Sayı: 1

A Fully Automatic Novel Method to Determine QT Interval Based on Continuous Wavelet Transform

Journal
Electrica
Pages
3103–3111
Publication Date
2017-03-27
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

In conclusion, the proposed algorithm is a fully automatic method to attain a high performance in the calculation of QT intervals at various ECG signals.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Nowadays, automatic recognition algorithm is being frequently utilized to extract the information concerning cardiac abnormalities.
📊
Key Findings & Data:The proposed algorithm was tested on MIT-BIH-NSR database given by QT database, then, it yielded the scores 15.17 milliseconds and root-mean-square error of 17.19 milliseconds at silver standard, 19.22 milliseconds and 20.22 milliseconds at gold standard, respectively.
💡
Conclusion & Impact:In conclusion, the proposed algorithm is a fully automatic method to attain a high performance in the calculation of QT intervals at various ECG signals.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:ECG Signal · QT interval · ECG signal classification

Abstract

Nowadays, automatic recognition algorithm is being frequently utilized to extract the information concerning cardiac abnormalities. In this study, a fully automatic novel method based on the continuous wavelet transform (CWT) was developed for QT intervals in various ECG signals. Especially, the determination of T-wave end is the paramount problem to be solved.The developed method was performed to find the beginning of QRS complexes and the end of T-wave. The proposed algorithm was tested on MIT-BIH-NSR database given by QT database, then, it yielded the scores 15.17 milliseconds and root-mean-square error of 17.19 milliseconds at silver standard, 19.22 milliseconds and 20.22 milliseconds at gold standard, respectively. In conclusion, the proposed algorithm is a fully automatic method to attain a high performance in the calculation of QT intervals at various ECG signals.

🔖

Cite This Article

YILMAZ, C., İŞCAN, M., YILMAZ, A. (2017). A Fully Automatic Novel Method to Determine QT Interval Based on Continuous Wavelet Transform. Electrica, Cilt: 17 Sayı: 1, 3103–3111. https://ajindex.com/articles/1017401

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (13)

  1. Goldberg, R. J., Bengtson, J., Chen, Z., Anderson, K. M., Locati, E., & Levy, D.,"Duration of the QT interval and total and cardiovascular mortality in healthy persons (The Framingham Heart Study experience)".,The American journal of cardiology, 67(1), 55-58.,1991
  2. Zhang, Q., Manriquez, A. I., Médigue, C., Papelier, Y., & Sorine, M.,“An algorithm for robust and efficient location of T-wave ends in electrocardiograms”,IEEE Transactions on Biomedical Engineering, 53(12), 2544-2552,2006.
  3. Goldenberg, I. L. A. N., Moss, A. J., & Zareba, W. QT interval: how to measure it and what is" normal". Journal of cardiovascular electrophysiology, 17(3), 333-336, (2006).
  4. Helfenbein, E. D., Zhou, S. H., Lindauer, J. M., Field, D. Q., Gregg, R. E., Wang, J. J.,. & Michaud, F. P. An algorithm for continuous real-time QT interval monitoring. Journal of electrocardiology, 39(4), S123-S127, (2006).
  5. Murray, A., McLaughlin, N. B., Bourke, J. P., Doig, J. C., Furniss, S. S., & Campbell, R. W.,“Errors in manual measurement of QT intervals”,British Heart Journal, 71(4), 386-390, (1994).
  6. McLaughlin, N. B., Campbell, R. W. F., & Murray, A.,“Accuracy of automatic QT measurement techniques”. Computers in Cardiology, Proceedings. 863-866. IEEE, 1993.
  7. Hayn, D., Kollmann, A., & Schreier, G.,“Automated QT interval measurement from multilead ECG signals”,Computers in Cardiology, 381-384, IEEE, 2006.
  8. Clifford, G. D., & Villarroel, M. C.,“Model-based determination of QT intervals”,Computers in Cardiology, 357-360, IEEE, 2006.
  9. Xue, Q., & Reddy, S. Algorithms for computerized QT analysis. Journal of electrocardiology, 30, 181-186. (1998). Alexander A. Suarez Leon et al, "Neural Network Approach for T wave End Detection: A comparison of Architectures", Comput. Cardiol., vol. 42, pp. 589-592, 2015. Mehmet İşcan; Cüneyt Yilmaz; Faruk Yi̇ği̇t, " T-wave end pattern classification based on Gaussian mixture model", DOI: 10.1109/SIU.2016.7496149, Pages 1953 - 1956, 2016.
  10. Mehmet İşcan, Faruk Yi̇ği̇t, Cüneyt Yilmaz," Heartbeat Pattern Classification Algorithm Based on Gaussian Mixture Model", Inter. Symp. on Med. Meas. and App., Italy,2016.
  11. Chesnokov, Y. C., Nerukh, D., & Glen, R. C.,“Individually adaptable automatic QT detector”. Computers in Cardiology,337-340, IEEE, 2006.
  12. Li, C., Zheng, C., & Tai, C. Detection of ECG characteristic points using wavelet transforms. IEEE Transactions on biomedical Engineering, 42(1), 21-28., (1995).
  13. Chudacek, V., Huptych, M., Novak, D., & Lhotska, L. Automatic QT inter