Journals / The Turkish Journal Of Occupational / Environmental Medicine and Safety / 2017 / Cilt: Volume 2 Sayı: İssue 1 (1) - 2.İnternational Congress Of Forensic Toxicology

MEASUREMENT UNCERTAINITY IN VALPROIC ACID CONCENTRATIONS

Pages
258–258
Publication Date
2017-02-16
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Laboratories should calculate measurement uncertainity and evaluate results according to spesific criterias.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:According to ISO uncertainity is a parameter associated with the result of measurement that characterizes the dispersion of the values that could reasonably be attributed to the measurand.
📊
Key Findings & Data:The aim of this study is to calculate measurement uncertainty of valproic acid by using internal quality control data and inter laboratory results to compare these calculated measurement uncertainties with total allowable error % (TEa %) value of CLIA'88.Between October 2015 and March 2016, the internal quality control datas were screened.
💡
Conclusion & Impact:Laboratories should calculate measurement uncertainity and evaluate results according to spesific criterias.
🔬Design:Research Article
📍Scope:2015 Verileri
⚙️Variables:MEASUREMENT UNCERTAINITY IN VALPROIC ACID CONCENTRATIONS

Abstract

According to ISO uncertainity is a parameter associated with the result of measurement that characterizes the dispersion of the values that could reasonably be attributed to the measurand. The aim of this study is to calculate measurement uncertainty of valproic acid by using internal quality control data and inter laboratory results to compare these calculated measurement uncertainties with total allowable error % (TEa %) value of CLIA'88.Between October 2015 and March 2016, the internal quality control datas were screened. The estimation of valproic acid measurement uncertainity was calculated according to ISO21748 guide. Inter laboratory comparison was executed to estimate bias. Valproic acid levels were determined using the immunoturbidimetric method on the Roche Cobas Integra 800 analyzer.Coefficient variations (CV) calculated from internal quality control analyses were 2.12, 2.46 and 3.01 at low, normal and high level of internal quality control sera values respectively. Total allowable error value of valproic acid was 9.94% and was not higher than desirable TEa% values of CLIA'88.Valproic acid is a widely-used first-generation antiepileptic drug, therapeutic range between 50-100 µg/mL, prescribed predominantly in migraine prophylaxis, epilepsy and psychiatric disorders. Careful clinical monitoring should be performed during the first 6 months of therapy with valproic acid. For this purpose, using uncertainty value is a good practice to interpret of patient result. Laboratories should calculate measurement uncertainity and evaluate results according to spesific criterias.

🔖

Cite This Article

AVCİOGLU, G., ERDOGAN, S., BAL, C., SEN, O., BARAN, P., EREL, O. (2017). MEASUREMENT UNCERTAINITY IN VALPROIC ACID CONCENTRATIONS. The Turkish Journal Of Occupational / Environmental Medicine and Safety, Cilt: Volume 2 Sayı: İssue 1 (1) - 2.İnternational Congress Of Forensic Toxicology, 258–258. https://ajindex.com/articles/1009116

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (1)

  1. Gamze AVCİOGLU, Serpil ERDOGAN, Ceylan BAL, Orhan SEN, Pervin BARAN, Ozcan EREL Ataturk Training and Research Hospital, Department of Clinical Biochemistry, Ankara, Turkey Yildirim Beyazit University Faculty of Medicine, Department of Public Health, Ankara, Turkey