Journals / İstanbul Tıp Fakültesi Dergisi / 2014 / Cilt: 77 - Sayı: 2

FOREIGN BODY IN THE EXTENSOR TENDON SHEATH

EKSTANSÖR TENDON KILIFINDAKİ YABANCI CİSİM: Olgu sunumu

Pages
26–28
Publication Date
2014-03-21
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

An unusual case of embedded metallic foreign body in the right extensor pollicis longus tendon sheath that induced symptoms mimicking De-Quervain’s disease was cured after surgical removal of the foreign body and reported here.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Foreign body is rarely seen in tendon sheaths.
📊
Key Findings & Data:Foreign body is rarely seen in tendon sheaths.
💡
Conclusion & Impact:An unusual case of embedded metallic foreign body in the right extensor pollicis longus tendon sheath that induced symptoms mimicking De-Quervain’s disease was cured after surgical removal of the foreign body and reported here.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Yabancı cisim · ekstansör · tendon kılıfı

Abstract

Foreign body is rarely seen in tendon sheaths. An unusual case of embedded metallic foreign body in the right extensor pollicis longus tendon sheath that induced symptoms mimicking De-Quervain’s disease was cured after surgical removal of the foreign body and reported here.

Özet

Yabancı cisimler tendon kılıflarında nadiren görülürler. Bu çalışmada, De-Quervain hastalığı semptomlarına yol açan ve cerrahi girişimle sağ ekstansör pollicis longus tendon kılıfına gömülen metalik yabancı cismin çıkarılmasıyla tedavi edilen olgu sunulmaktadır.

🔖

Cite This Article

ÖZDEMİR, A., ERGÜN, S. S., KARAALTIN, M., YILDIZ, K., DUYGU, Ç. (2014). FOREIGN BODY IN THE EXTENSOR TENDON SHEATH. İstanbul Tıp Fakültesi Dergisi, Cilt: 77 - Sayı: 2, 26–28. https://ajindex.com/articles/100858

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (6)

  1. Baskar S, Mann JS, Thomas AP, Newton P. Plant thorn tenosynovitis. J Clin Rheumatol 2006;12: 137– 1 Chan JK, Lamyman M, Heywood A. Foreign body migration within the flexor sheath. J Hand Surg Eur Vol. 2010; 35:595-7.
  2. Chien AJ, Jacobson JA, Martel W, Kabeto MU, Marcantonio DR. Focal radial styloid abnormality as a manifestation of de Quervain tenosynovitis. AJR Am J Roentgenol. 2001;177:1383-6. Howden MD. Foreign bodies within finger tendon sheaths demonstrated by ultrasound: two cases. Clin Radiol 1994; 49:419-20.
  3. Morris L, Stevens A, Doherty M. Chronic flexor tenosynovitis: missed diagnosis for a decade. Ann Rheum Dis 1996; 55:597-9. Rida A. A foreign body in a tendon sheath. J Bone Joint 1961; 43-A:282-3.
  4. Seyhan H, Kopp J, Horch R. De Quervain's stenosing tendovaginitis, one of the most common conditions affecting the hand. MMW Fortschr Med. 2006;148:33-5.
  5. Yang SS, Bear BJ, Weiland AJ. Rupture of the flexor pollicis longus tendon after 30 years due to migration of a retained foreign body. J Hand Surg Br 1995; 20:803-805.
  6. Tuncer S, Ozcelik IB, Mersa B, Kabakas F, Ozkan T. Removal of glass fragments from hand injuries. Ann Plas Surg 2011; 67:114-8.