Dergiler / Florence Nightingale journal of nursing (Online) / 2020 / Cilt: 28 - Sayı: 2

The Effect of Cuff Size on Blood Pressure Measurement in Obese Surgical Patients: A Prospective Crossover Clinical Trial

The Effect of Cuff Size on Blood Pressure Measurement in Obese Surgical Patients: A Prospective Crossover Clinical Trial

Sayfa
205–212
DOI
—

Abstract

Aim: This study aimed to determine the effect of a cuff properly sized for mid-upper arm circumference on blood pressure measurement in obese surgical patients.Method: This prospective crossover clinical trial was conducted with 100 patients who had body mass index ≥30 kg/m2 and mid-upper arm circumference ≥27 cm and were admitted to the general surgery unit of a medical faculty hospital in İstanbul, Turkey between January 1, 2015, and December 31, 2015. Blood pressure of the patients was measured using a small-sized adult cuff and a cuff properly sized for mid-upper arm circumference.Results: Among the patients, 39% were morbidly obese and 67% had mid-upper arm circumference between 35 and 44 cm. Systolic blood pressure of the patients with a small adult cuff was 20.78 mmHg higher than that obtained with a cuff properly sized for mid-upper arm circumference, and their diastolic blood pressure was 10.15 mmHg higher on average (p