Dergiler / Diagnostic and Interventional Radiology / 2020 / Cilt: 26 - Sayı: 3

Embolization using warmed glue via the triaxial microballoon occlusion system for various vascular disorders

Sayfa
241–244
DOI
—

Özet

PURPOSEWe aimed to illustrate the benefits of using warmed glue for viscosity reduction via the triaxial microballoon system for the treatment of various vascular disorders.METHODSSeven patients who underwent 10 treatment sessions for hemoptysis, type II endoleak, post-pancreatic surgical bleeding, spontaneous retroperitoneal bleeding, or ovarian tumor bleeding were evaluated based on technical and clinical outcomes. In the procedure, the triaxial system, consisting of a 4.5 F guiding catheter, a 2.8 F microballoon catheter, and a 1.9 F no-taper microcatheter, was advanced into the target lesion. Glue (33% n-butyl cyanoacrylate mixed with Lipiodol) warmed to 40°C was injected under balloon occlusion.RESULTSThe common hepatic, right bronchial, intercostals, internal mammary, costocervical, lateral thoracic, superior thoracic, thoracoacromial, inferior thyroid, iliolumbar, lumbar, internal pudendal arteries, and branch of the inferior mesenteric artery were successfully embolized; 100% technical success and 100% clinical success were obtained after each session.CONCLUSIONOur modified balloon-occluded glue embolization may lead to better handling with more distal glue penetration capability.