Dergiler / Journal of Clinical Research in Pediatric Endocrinology / 2015 / Cilt: 7 - Sayı: 1

Capillary Bedside Blood Glucose Measurement in Neonates: Missing a Diagnosis of Galactosemia

Sayfa
83–86
DOI
—

Abstract

A number of factors may lead to inaccuracy in measurement of capillary blood glucose with a glucometer. Measurement of other carbohydrate molecules such as galactose and fructose along with glucose can potentially be a cause of error. We report a newborn patient who was referred to our hospital with conjugated bilirubinemia, hepatomegaly and high capillary blood glucose levels measured with a glucometer. Simultaneous biochemical measurements revealed normal blood glucose levels. Further investigation led to a diagnosis of classical galactosemia. Capillary blood glucose level measured with glucometer also dropped to normal values following cessation of breastfeeding and initiation of feeding with a lactose-free formula