Dergiler / Gazi University Journal of Science / 2018 / Cilt: 31 - Sayı: 1

Application of 1,6-hexanedithiol and 1-hexanethiol self-assembled monolayers on polycrystalline gold electrode for determination of Fe(II) using square wave voltammetry

Sayfa
53–64
DOI
—

Abstract

Monolayer films modified polycrystalline gold electrode has been fabricated by using self assembled monolayer method of 1,6-hexanedithiol and 1-hexanethiol and used for electro-catalytic oxidations of iron(II). A calibration curve was obtained for Fe(II) in a wide concentration range from 5.00×10-8 mol.L−1 to 3.85×10-5 mol.L−1 and detection limit of 1.6×10-8 mol.L−1 on the Au-HDT electrode. Additionally, on the Au-HT electrode, the linear range from 1.00×10−8 mol.L−1 to 2.56×10−5 mol.L−1 and detection limit of 3.20×10−8 mol.L−1 for the determination of Fe(II) were achieved. Validity of the method and applicability of the electrodes are successfully tested by determination of Fe(II) in real samples.