Implant retained overdentures are the best treatment solutions for long time edentulism. However especially for un-reinforced mandibular overdentures with locator attachments, if the naturel dentition exists on the opposing arch, the most common failure is fracture of the acrylic denture base around the attachment clips. In this case report, acrylic base material of the fractured mandibular implant retained overdenture was reinforced with bidirectional e-glass fibers.

Abstract

Uzun süreli tam dişsizliklerde implant destekli hareketli protezler en iyi tedavi yöntemidir. Ancak karşıt arkın doğal dentisyon olduğu durumlarda özellikle locator tutuculu güçlendirilmemiş alt hareketli protezlerde, tutucu klips çevresinde akrilik kaide materyalinin kırılması en sık görülen başarısızlıktır. Bu vaka raporunda,akrilik kaide materyali kırılan implant destekli alt protez çift yönlü cam fiber ile güçlendirilmiştir.