Journals / Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi / 2026 / Cilt: 32 Sayı: 4
Numerical investigation of design of a passive micromixer compound shape on split and recombination concept
- Pages
- 638–645
- Publication Date
- 2025-12-30
Abstract
Microchannels are a key component of these devices, and micromixers are the heart of these channels. The related study aims to produce micromixers with high efficiency with a simple shape. This work presents the design and numerical performance analysis of the flow using Computational Fluid Dynamics (CFD). This work is based on the SAR (Split and Recombination) concept with a zigzag shape. The mixing was investigated over a wide range of Re numbers (1-100). Four factors with three levels were optimized by the Taguchi method to achieve the optimal shape: angle, several periods, the ratio between width to diameter, width, and depth. The index of mixing is evaluated and focused on the variance of the fraction of the mass in the mixture. As a result, the index of mixing is enhanced with varied Reynolds numbers. The mixer with a 70°, 4-period (w/d=0.125) and (w/t=1) design was the optimal choice.
Özet
Mikro kanallar cihazların bir parçasıdır ve mikro karıştırıcılar kanalların kalbidir denilebilir. İlgili çalışma, akışın tasarımını ve performans analizini Hesaplamalı Akışkanlar Dinamiği (HAD) ile sayısal olarak açıklamaktadır. Bu çalışma, zikzak şekilli SAR konseptine dayanmaktadır. Karıştırma, geniş bir Re sayısı aralığında (1-100) incelenmiştir. En uygun şekli elde etmek için üç seviyeli dört faktör Taguchi yöntemi ile optimize edilmiştir; açı, periyot, genişlik ile çap arasındaki oran arasındaki ilişki için de genişlik ve derinlik incelenmiştir. Karıştırma indeksi, karışımdaki kütle kesrinin varyansına odaklanarak değerlendirilmektedir. Sonuç olarak, karıştırma indeksi değişen Reynolds sayılarıyla arttığı görülmüştür. Karıştırıcıdaki en iyi tasarım 70o, 4-periyotlu, (w/d=0.125) ve (w/t=1) koşullarında elde edilmiştir.
Cite This Article
References (29)
- [1] Stone A, Stroock D, Ajdari A. “Engineering flows in small devices microfluidics toward a lab-on-a-chip”. Annual Review of Fluid Mechanics, 36, 381-411, 2004.
- [2] Whitesides M. “The origins and the future microfluidics”. Nature, 442(7101), 368-373, 2006.
- [3] Erickson D. “Towards numerical prototyping of labs-on-chip: modeling for integrated microfluidic devices”. Microfluidics and Nanofluidics, 1(4), 301-318, 2005.
- [4] Damljanovic V, Christoffer Lagerholm B, Jacobson K. “Bulk and micropatterned conjugation of extracellular matrix proteins to characterized polyacrylamide substrates for cell mechanotransduction assays”. BioTechniques, 39(6), 847-851, 2005.
- [5] Roumanie M, Delattre C, Mittler F, Marchand G, Meille V, de Bellefon C, Pouteau P. “Enhancing surface activity in silicon microreactors: Use of black silicon and alumina as catalyst supports for chemical and biological applications”. Chemical Engineering Journal, 135, 317-326, 2008.
- [6] Singh K, Anderson D, Meijer E. “Understanding and optimizing the SMX static mixer”. Macromolecular Rapid Communications, 30(4‐5), 362-376, 2009.
- [7] Tromeur M, Mahé C, Schwesinger N, Tranchant F. “Micromixers to produce cosmetic emulsions”. International Journal of Cosmetic Science, 25(1‐2), 1-4, 2003.
- [8] Stefanidis D, Vlachos G. “High vs. low temperature reforming for hydrogen production via microtechnology”. Chemical Engineering Science, 64(23), 4856-4865, 2009.
- [9] Liu Y, Deng Y, Zhang P, Liu Z, Wu Y. “Experimental investigation of passive micromixers conceptual design using the layout optimization method”. Journal of Micromechanics and Microengineering, 23(7), 075002, 2013.
- [10] Lin H, Storey D, Oddy H, Chen H, Santiago G. “Instability of electrokinetic microchannel flows with conductivity gradients”. Physics of Fluids, 16(6), 1922-1935, 2004.
- [11] Capretto L, Cheng W, Hill M, Zhang X. “Micromixing within microfluidic devices”. Topics in Current Chemistry, 304, 27-68, 2011.
- [12] Niu XZ, Lee YK. “Efficient spatial-temporal chaotic mixing in microchannels”. Journal of Micromechanics and Microengineering, 13(3), 454-462, 2003.
- [13] Razavi Bazaz S, Sayyah A, Hazeri Amir H, Salomon R, Abouei Mehrizi A, Ebrahimi Warkiani M. “Micromixer research trend of active and passive designs”. Chemical Engineering Science, 293, 120028, 2024.
- [14] Wei H, Le P. “Magnetic fluid micromixer with tapered magnets”. Journal of Applied Physics, 105(7), 07B523, 2009.
- [15] Granados-Ortiz F, Garcia-Cardosa M, Ortega-Casanova J. “Effect of wall modifications in a vortex shedding-based mechanical micromixer for heat/mass exchange”. European Journal of Mechanics-B/Fluids, 92, 174-190, 2022.
- [16] Hossain S, Lee I, Kim M, Kim Y. “A micromixer with two-layer serpentine crossing channels having excellent mixing performance at low Reynolds numbers”. Chemical Engineering Journal, 327, 268-277, 2017.
- [17] Chen X, Zhao Z. “Numerical investigation on layout optimization of obstacles in a three-dimensional passive micromixer”. Analytica Chimica Acta, 964,142-149, 2017.
- [18] Chen X, Li T, Zeng H, Hu Z, Fu B. “Numerical and experimental investigation on micromixers with serpentine microchannels”. International Journal of Heat and Mass Transfer, 98, 131-140, 2016.
- [19] Viktorov V, Mahmud R, Visconte C. “Design and characterization of a new HC passive micromixer up to Reynolds number 100”. Chemical Engineering Research and Design, 108, 152-163, 2016.
- [20] Ruijin W, Beiqi L, Dongdong S, Zefei Z. “Investigation on the splitting-merging passive micromixer based on Baker's transformation”. Sensors and Actuators B: Chemical, 249, 395-404, 2017.
- [21] Raza W, Hossain S, Kim Y. “Effective mixing in a short serpentine split-and-recombination micromixer”. Sensors and Actuators B: Chemical, 258, 381-392, 2018.
- [22] Gidde R, Pawar M, Ronge P, Shinde B, Misal D, Wangikar S. “Flow field analysis of a passive wavy micromixer with CSAR and ESAR elements”. Microsystem Technologies, 25(3), 1017-1030, 2019.
- [23] Shah I, Kim W, Kim K, Doh H, Choi H. “Experimental and numerical analysis of Y-shaped split and recombination micro-mixer with different mixing units”. Chemical Engineering Journal, 358, 691-706, 2019.
- [24] Gayen B, Manna N, Biswas N. “Enhanced mixing quality of ring-type electroosmotic micromixer using baffles”. Chemical Engineering and Processing-Process Intensification, 189, 109381, 2023.
- [25] Lotfiani A, Rezazadeh G. “A new two-layer passive micromixer design based on SAR-vortex principles”. International Journal of Chemical Reactor Engineering, 19(3), 309-329, 2021.
- [26] Li D, Hou X, He Y, Wu J. “Numerical simulation of the mixing performance of a novel SAR micromixer with hollow mixing chamber and diverse connecting channel”. Chemical Engineering and Processing-Process Intensification, 212, 110282, 2025.
- [27] Celik B, Ghia U, Roache J, Freitas J. “Procedure for estimation and reporting of uncertainty due to discretization in CFD applications”. Journal of Fluids Engineering, 130(7), 078001, 2008.
- [28] Ali S. M, Doolan J, Wheatley V. “Grid convergence study for a two-dimensional simulation of flow around a square cylinder at a low Reynolds number”. 7th International Conference on CFD in the Minerals and Process Industries, Melbourne, Australia, 9-11 December 2009.
- [29] Verzicco R, Pirozzoli S, Leonardi S. “Vortical Structures and Wall Turbulence”. European Journal of Mechanics- B/Fluids, 55, 241-241, 2016.